The environmental tester is specially designed for long-term monitoring of climatic conditions in, for example, offices, classrooms or lecture halls. The air quality meter has various sensors. Among other things, the air quality meter has a carbon dioxide sensor up to 40,000 ppm, a temperature sensor with a measuring range between 0 ... 50 °C, an ambient humidity sensor with a measuring range between 0 ... 100% RH and a barometer with a measuring range between 300 ... 2000 hPa. The air quality meter can therefore be used in many applications due to its large number of sensors. The measured values are shown directly on the e-paper display of the air quality measuring device. A good / medium / bad rating of the carbon dioxide content in the ambient air is also displayed.
During the measurement, the environmental tester can automatically record the measured values. The measured values are saved as .csv on the micro SD card. This means that the measurement data recorded by the air quality meter can be imported directly into the company's own database. The measurement data from the air quality measuring device can be displayed in graphical and tabular form via the software.
The environmental tester has an alarm function. This alarm mode can be used to set limit values for the individual sensors. As soon as the set threshold value is reached in the air quality meter, this is indicated acoustically and visually via the alarm LED. After the air quality meter falls below the threshold value again, the alarm switches off again automatically.
Environmental Tester AQD 50
Temperature Measuring range 0 ... +50 ºC / 32 ... 122 ºF Resolution 0.1 ºC Accuracy ±0.15 ºC @ 0 ... 20 ºC / 32 ... 60 ºF ±0.1 ºC @ 20 ... 50 ºC / 68 ... 122 ºF Ambient Humidity Measuring range 0 ... 100 % RH Resolution 0.1 % RH Accuracy ±1.5 % RH @ 0 … 80 % RH ±2 % RH @ 80 … 100 % RH Atmospheric Pressure Measuring range 300 ... 2000 hPa Resolution 0.1 hPa Accuracy ±2 hPa @ 25 ºC / 77 ºF and 750 ... 1100 hPa ±4 hPa @ 0 ... +50 ºC / 32 ... 122 ºF and 300 ... 1200 hPa CO2 Measuring range 0 ... 40000 ppm Resolution 1 ppm Accuracy ±(30 ppm + 3% of measured value) @ 400 ... 10000 ppm @25 ºC / 77 ºF ±(6 ... 10 % of measured value) @ 0 ... 400 ppm or 10000 ... 40000 ppm Temperature Stability 2.5 ppm/ºC @ T = 0 ... 50 ºC / 32 ... 122 ºF, 400 ... 10000 ppm Further Specifications Display 2.7" E-Paper Battery life* ca. 10 months for the measurement intervals: Temperature: 60 minutes Ambient humidity: 60 minutes Atmospheric pressure: 60 minutes CO2: 60 minutes *further information on battery life can be found in the instructions Storage capacity MicroSD card with 32 GB of storage for a total of 1 trillion measuring points Sampling intervals 30s, 1 min, 2 min, 10 min, 15 min, 30 min, 1 h, 2 h, 6 h, 12 h, 24 h Power supply battery 7.4 V DC / 3400 mAh, Li-Ion battery Power supply mains power adapter 12 V DC / 1.5 A Protection class IP30 Operating conditions 0 ... +50 ºC / 32 ... 122 ºF 0 ... 100 % RH, non-condensing Storage conditions -20 ... +60 ºC / -4 ... 140 ºF 0 ... 100 % RH, non-condensing Dimensions 128.5 x 88.5 x 41 mm / 1.1 x 3.4 x 1.6" Weight 300 g / 10.5 oz