top of page

This Gas Detector is a unique gas meter which protects against a specific gas, inflammable or toxic. The Gas Detector Gasman warns with a penetrating alarm and an optical signal (useful when there are loud noises in the surrounding area) of the existence of dangerous gas concentrations and shows on screen the value of the gas measurement. In addition with this gas meter you are able to save measurements and transmit them onto the computer for evaluation. For that, it is necessary to require the additional option of data logger and optional software. The function of logger will allow you to keep all the values in the meter with a quota of measurement from 1 minute to a total of 900 hours. The data saved in the apparatus can be, at any time, transferred onto the computer or laptop for later evaluation. The Gas Detector can be calibrated and certified according to DIN ISO.

Gas Detector Gasman-FL | 易燃氣體探測

  • Technical specifications (12 gases choice)
    Typical measurement ranges and alarm adjustments
    Parameter/Gas Symbol Range Alarm
    Inflammable gas CH4 0 ... 100% LEL 20% LEL
    Oxygen O2 0 ... 25% v/v 19% and 23% v/v
    Hydrogen sulfide H2S 0 ... 100 ppm 5 ppm
    Carbon dioxide CO2 0 ... 5 % v/v 0.5 and 1.5% v/v
    Carbon monoxide CO 0 ... 500 ppm 30 ppm
    Sulfur dioxide SO2 0 ... 20 ppm 1 ppm
    Chlorine * CL2 0 ... 5 ppm 0.5 ppm
    Nitrogen dioxide* NO2 0 ... 10 ppm 1 ppm
    Phosphine PH3 0 ... 5 ppm 0.5 ppm
    Ammonia NH3 0 ... 100 ppm 25 ppm
    Hydrogen H2 0 ... 1000 ppm 100 ppm
    Ozone O3 0 ... 1 ppm 0.1 ppm

     

  • Sensors (sensors are exchangeable) Response time (T90) Life
    Methane 20 s 5 years
    Toxic gases 20 s 3 years
    Oxygen 10 s minimum 1 year
    Acoustic alarms

    - 85 dB (a) to 1 m of distance (adjustable tone)
    - Tone of regular control that can be disconnected
    - Prolonged tone in case of low battery in the gas meter

    Optical alarm

    - Very clear and flashing LED
    - Type of alarm Indicator
    - Green LED with low frequency flashing as operating indicator

    Vibration alarm - Meter vibrates additionally as a complement to the optical and acoustic alarms
    Autozero function - In order to adapt the meter to different environmental conditions of measurement (always activate the clean air function)
    Display - LCD with backlight
    - 10 mm lines to indicate the gas value
    - Symbols for: Max Hold, Batt Low, calibration
    ground zero, alarm 1 and 2, 15 min and 8 h, alarms TWA
    Measurement values memory Adjustable memory intervals, max. capacity of 900 h prolonged with measurement quota of 1 min (depends on the gas concentration)
    Power supply Toxic gases and oxygen - interchangeable lithium battery
    - 1 year in normal use conditions
    in order to load, the charging station is necessary - 2 cells of nickel-metal hydride (reloadable), 8 ... 10 hours of operative duration
    Environmental conditions -20° C ... +55° C / -4° F ... +131° F
    0 ... 99 % R.H. non condensed
    Housing IP 65/67
    Dimensions 90 mm x 48 mm x 24 mm
    3.5 in x 1.9 in x 0.94 in
    Weight max. 130 g / 0.29 lbs (battery included)
    Norms EN 50014, EN 50020, EN 50018, EN 55022
    clase B, EN 50081-2, Ex 95C2348X, Ex 65C2349, Ex 95Y1350, IEC 801-3, EN 50082-2, IEC 61508, EN 61779, EN 50721
    Authorisation EEx ia (d) IIC T3 or T4
    ATEX II 1G EEx ia IIC T4 (-20 ... +55 °C)
    (Toxic gases and oxygen)
    ATEX II 2G EEx ia d IIC T4 (inflammable gases)
bottom of page