The HVAC meter PCE-893 is suitable for simple temperature measurements. The emissivity of the surface can be adjusted on the PCE-893 HVAC meter. Thus, the HVAC meter PCE-893 is suitable for almost all surfaces. The dual laser of the HVAC meter PCE-893 marks the exact center of the measurement spot. This helps the user considerably with non-contact temperature measurement. The HVAC meter PCE-893 has a backlit display. In addition to the emissivity setting, the user can set limit value alarms over the entire measuring range of the PCE-893 HVAC meter. The measuring range is from -50 °C to + 1200 °C / -58 ... 2192 °F. The measuring spot ratio of the HVAC meter PCE-893 is 50:1.
In addition to the infrared measurement, a variety of thermocouples Type-K can be connected to the HVAC meter. Here measurements up to 1370 °C / 2498 °F are possible. The included software and the USB port on the HVAC meter allow the operator to analyze and store all measurement data on the PC both graphically and in a table.
HVAC Meter PCE-893
- Dual laser shows the spot center
- Adjustable emissivity
- Illuminated LCD
- Measured value transmission to a PC
- Non-contact temperature measurement
- Measurement spot ratio 50: 1 infrared optics
- Temperature measurement up to 1200 °C / 2192 °F
- Thermocouple type-K can be connected
Typical applications of the HVAC meter PCE-893
- Food monitoring
- Hygiene tests
- Road construction
- Control cabinet monitoring
- Heating and air conditioning technology
- Production monitoring
- Temperature measurement on motors
- Electronic components
- Fuse box
Infrared measurement Infrared measurement -50 ... 1200 °C / -58 ... 2192 °F Resolution 0.1 at display <1000 1 at display >1000 Accuracy ±3 °C / 5.4 °F (-50 ... 20 °C / -58 ... 68 °F) ±1 % ±1 °C / ±1.8°F (20 ... 500 °C / 68 ... 932°F) ±1.5 % (500 ... 1000 °C / 932 ... 1832 °F) ±2 % (1000 ... 1600 °C / 1832 ... 2912 °F) The accuracies apply at an ambient temperature of 23 ... 25 °C (73 ... 77 °F) Repeatability ±1.5 °C / 2.7 °F (-50 ... 20 °C / -58 ... 68 °F) ±0.5 % or ±0.5 °C / 0.9 °F (20 ... 1000 °C / 68 ... 1832 °F) ±1.0 % (1000 ... 1600 °C / 1832 ... 2912 °F) Thermocouple Measuring range -50 ... 1370 °C / -58 ... 2498 °F Resolution 0.1 at display <1000 1 at display >1000 Accuracy ±2.5 °C / ±3.6°F (-50 ... 0 °C / -58 ... 32°F) ±0.5 % ±1.5 °C / 3 °F (0 ... 1370 °C / 32 ... 2498 °F) Measurement spot ratio 50:1 Response time 150 ms Spectral range 8 ... 14 µm Emissivity Adjustable 0.10 ... 1.0 Display overrange The display will show "----" Display laser diode LCD with backlight Output <1 mW Wavelength 630 ... 670 nm Classification Class 2 Power supply 9 V block battery Operating conditions 0 ... +50 °C / 32 ... 122 °F Storage conditions -10 ... +60 °C / 14 ... 140 °F Weight ca. 282 g without battery Dimensions 200 x 55 x 150 mm / 7.8 x 2.1 x 5.9"