EM 886 is a portable handheld multifunctional digital device used to measure sound, light, humidity, temperature, AC / DC current, electrical resistance, capacitance and frequency. This multipurpose, all-in-one measuring instrument has myriad applications in a plethora of industries and environments.
As a sound level meter, the measuring device uses a built-in electric condenser microphone to measure noise in factories, schools, offices, airports and more. It can also be used to check the acoustics of studios, auditoriums and sound system installations.
As a light meter, the device uses a built-in silicon diode to measure illuminance and is fully cosine corrected for the angular incidence of light.
For temperature measurement, the device uses an external semiconductor sensor with a type K thermocouple (included in delivery contents).
Multifunction Illuminometer EM 88
Measurement range
35 ... 100 dB
Resolution
0.1 dB
Frequency range
30 Hz ... 10 kHz
Frequency weighting
C
Time weighting
Fast
Accuracy
± 5 dB at 94 dB, 1 kHz sine wave
Microphone
Internal, electric condenser
Light
Measurement range
4,000 ... 40,000 lux (40,000 lux range reading x 10)
Overrate display
Highest digit of "OL"
Accuracy
± 5 % measurement value + 10 digits
(calibrated to standard incandescent lamp at color temperature 2856k)
Repeatability
± 2 %
Temperature characteristic
± 0.1 % / °C
Sensor
Internal, silicon photodiode with filter
Humidity
Measurement range
33 ... 99 % relative humidity (RH)
Resolution
1 % RH
Accuracy
± 3 % measurement value + 5 % RH
Temperature
Measurement range
Indoor: 0 ... +50 °C
Type K: -20 ... +1300 °C
Resolution
Indoor and Type K to +400 °C: 0.1 °
Type K to +1300 °C: 1 °
Accuracy
± 3 % measurement value ± 3 °C
Electrical
AC / DC current (auto-ranging for uA and mA)
Measurement range
ResolutionAccuracy
400 uA / 4000 uA / 40 mA / 400 mA / 10 A
0.1 uA / 1 uA / 10 uA / 100 uA / 10 mA± 1 % measurement value ± 2 digits (up to 40 mA DC)
± 1.2 % value ± 2 digits (up to 400 mA DC / 40 mA AC)
± 1.5 % value ± 2 digits (up to 400 mA AC)
± 2 % value ± 5 digits (up to 10 A)
Resistance (auto-ranging)
Measurement range
Resolution
Accuracy
400 Ω / 4 kΩ / 40 kΩ / 400 kΩ / 4 MΩ / 40 MΩ
0.1 Ω / 1 Ω / 10 Ω / 100 Ω / 10 kΩ / 1 MΩ
± 1.5 % value ± 4 digits (up to 400 Ω)
± 1.5 % value ± 2 digits (up to 400 kΩ)
± 2 % value ± 2 digits (up to 4 MΩ)
± 2.5 % value ± 2 digits (up to 40 MΩ)