SLT-TRM is a class II (type 2) sound level, sound pressure level (SPL), decibel (dB) or noise meter with audible or visual alarm output capability. SLT-TRM is used for long-term, continuous monitoring of occupational noise exposure limits in industrial environments such as foundries, factories and manufacturing production floors. The measuring device consists of a wall-mountable acoustic sensor on a 1.5 m / 4.92' long cable and a transmitter.
Sound Level Meter SLT-TRM
Measuring range 30 ... 130 dB in 3 ranges:
I. 30 ... 80 dB(A)
II. 50 ... 100 dB(A)
III. 80 ... 130 dB(A)Resolution 0.1 dB Accuracy ±1.5 dB Frequency weighting A Power supply Via transmitter Cable length (sensor to transmitter) 1.5 m / 4.92' Operating conditions 0 ... +50 °C / +32 ... +122 °F, max. 85 % RH Microphone 1/2" precision electret Standard IEC 61 672 (Class II) Transmitter
Housing
ABS plastic
Power supply 90 ... 260 AC V Calibration Adjustable by set screw Output 4 ... 20 mA Protection class IP 54 ingress protection rating Operating conditions 0 ... +50 °C / +32 ... +122 °F, max. 85 % RH