top of page

Vibrating Wire Load Cell Load Cells are designed to measure loads in strut, earth anchor. Once loaded on cylindrical cell, it slightly strained. 
At this time, a plucking coil senses the changes in the frequency of vibrating wire and then transmitted to V.W. Read out 
and shown in required units.

Vibrating Wire Load Cell

  • Product V.W Load Cell
    Rated Capacities 100ton ~ 150tons
    (Others per customer’s requirement)
    Over Range Capacity 150% full scale
    Sensitivity ±0.025%
    Resolution 0.025% full scale minimum
    Accuracy ±0.5% to ±1% full scale
    (in case of high capacity, ±0.5 to ±1% full scale)
    Temperature Range -20℃ ~ +80℃
    Excitation Method pluck or sweep
bottom of page